QR Multi-Core Railway Signal Cable

Application:

Branch line feeding, light signalling, track switching, ETCS and boom gates. Suitable for direct burial and specifically designed for Australian conditions in accordance with S.07.4211.29

Benefits

Easy to Install

Class 2 stranding and cable fillers make for easy stripping and terminating

Termite and vermin protected

UV stabilised polyamide 12 nylon jacket shields the cable from termites and vermin

Heavy Duty

Sacrificial sheath protects the cable during installation

Features

Oxygen free plain annealed copper wire
Stranded circular conductors are suitable for fixed installations
RoHS compliant to comply with European environmental requirements
V90 insulation and 5V90 sheath for high ambient temperature applications and long term durability
Metre marked

Construction

Termite Barrier PA 12 Nylon
Outer Sheath 5V90 PVC
Colours

White with black numbering

Conductor

Oxygen free tinned annealed copper wire, class 2

Insulation

V90 PVC

Inner Sheath

5V90 PVC

Ratings

Temperature

-10°C to + 90°C

Voltage

0.6/1kV

Applicable Standards

AS/NZS1125, AS/NZS3808, AS/NZS5000.1, AS/NZS1660.5.6, IEC 60228, IEC 60332-1, S.07.4211.29

Minimum Service Temperature -10°C

Maximum Service Temperature 90°C

Maximum Short Circuit Temperature 160°C (Max 5s)

Impact Resistant

Abrasion Resistant

Chemical And Oil Resistant

Flame Non-Propagation

UV Resistant

Minimum Recommended Bend Radius Fixed 12 x OD

Products

Code Application No. Of Cores x Conductor CSA mm² STRANDING No. of Strands/mm NOMINAL DIAMETER mm WEIGHT Kg/km Enquire About
19173 QR Item 1.2.1 4 x 1.5 1/1.38 14.9 267
19174 QR Item 1.2.2 8 x 1.5 1/1.38 17.4 394
19175 QR Item 1.2.3 10 x 1.5 1/1.38 19.6 492
19176 QR Item 1.2.4 20 x 1.5 1/1.38 23.8 791
48487 QR Item 1.2.5 30 x 1.5 1/1.38 27.3 1085
48488 QR Item 1.2.6 50 x 1.5 1/1.38 34.9 1707