- Braids & Terminated Braids
-
Control Cable
- ARTC Single and Multi Pair Railway Signal Cables
- Control Cable
- PTA Multi Pair Railway Signal Cables - Type K
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Copper Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Double Insulated (SDI) Cable
- SafeX125 - LSZH 125°C - Hook Up ELV Single Core Tinned Copper Cable
- SafeX125 Multi Core - LSZH 125°C - Tinned Copper Cables
- Sydney Trains - Multi-Core Power Cables
- Sydney Trains - Multi-Core Signal Cables
-
Data and Instrument
- ARTC Single and Multi Pair Railway Signal Cables
- Data & Instrument
- PTA Multi Pair Railway Signal Cables - Type K
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Copper Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Double Insulated (SDI) Cable
- SafeX125 - LSZH 125°C - Hook Up ELV Single Core Tinned Copper Cable
- SafeX125 Multi Core - LSZH 125°C - Tinned Copper Cables
- Type 9 Machine Cable
- EMC/VSD Cables
- Flexible Earths
- Glass Braided Silicone Rubber Cables 150 - 200
- Glass Insulated, Pure Nickel Single Core Cables 350
-
Halogen Free Cables
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Copper Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Double Insulated (SDI) Cable
- SafeX125 - LSZH 125°C - Hook Up ELV Single Core Tinned Copper Cable
- SafeX125 - Variable Speed Drive (VSD) Cable
- SafeX125 Multi Core - LSZH 125°C - Tinned Copper Cables
- XL co-polymer halogen free cables BETAflam 145 - Multi Core
- XL co-polymer halogen free cables BETAtherm 145 - Single Core
-
High Temperature
- Glass Insulated, Nickel Conductor Single Core Cables 350°C
- Glass Insulated, Nickel Conductor Single Core Cables 350°C Double Fine
- Glass Insulated, Nickel Conductor Single Core Cables 350°C Super Fine
- Glass Insulated, Tinned Copper Single Core Cables 150°C
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Copper Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Double Insulated (SDI) Cable
- SafeX125 - LSZH 125°C - Hook Up ELV Single Core Tinned Copper Cable
- SafeX125 Multi Core - LSZH 125°C - Tinned Copper Cables
- Silicone Rubber Multi Core - 150°C
- Silicone Rubber Single Core - 150°C
- Silicone Rubber Single Core - 200°C
- Silicone Rubber/ Glass Braided Single Core 150°c
- Silicone Rubber/ Glass Braided Single Core 200°C
- Tinned Copper Lighting Discharge Cable 150°C
- Low Voltage
-
Marine Cable
- DC Figure 8 Flexible Tinned Copper Cable
- Heavy Duty Multi-Core Flexible Tinned Copper PVC Cable
- Marine Cable battery and Starter
- Marine Cable Figure 8
- Marine Cable Single Core
- Marine Cable Twin Sheathed Flat
- Multi-Core Rubber Cables
- Ordinary Duty Multi-Core Flexible Tinned Copper PVC Cable
- Single Core Rubber Cables
- Microphone Cable
-
Mining Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Copper Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Double Insulated (SDI) Cable
- SafeX125 Multi Core - LSZH 125°C - Tinned Copper Cables
- Type 1 Machine Cable
- Type 3 Machine Cable
- Type 9 Machine Cable
- Vari-Flex EMC / VSD Cable - XLPE - Braid and foil screen
- Vari-Flex EMC / VSD Cable - XLPE - Braid screen
- PVC Flexible
-
Power Cables
- ARTC approved single core and multi core railway power cable
- ARTC approved single core and multi core railway signal cable
- DC Figure 8 Flexible Tinned Copper Cable
- PTA Multi-Core Railway Power Cable
- PTA Multi-Core Railway Signal Cable - Type F
- QR Multi-Core Railway Power Cables
- QR Multi-Core Railway Signal Cable
- Sydney Trains - Multi-Core Power Cables
- Sydney Trains - Multi-Core Signal Cables
- Sydney Trains - Single Core Power Cables
- Traction Return Bonding and Track Connection
- VRIOGS Power and Signal Cables
- Pump Cable
-
Railway Cables
- ARTC approved single core and multi core railway power cable
- ARTC approved single core and multi core railway signal cable
- ARTC Single and Multi Pair Railway Signal Cables
- Axle Counter Cables
- DC Figure 8 Flexible Tinned Copper Cable
- PTA Multi Pair Railway Signal Cables - Type K
- PTA Multi-Core Railway Power Cable
- PTA Multi-Core Railway Signal Cable - Type F
- QR Multi-Core Railway Power Cables
- QR Multi-Core Railway Signal Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Copper Cable
- SafeX125 - LSZH 125°C - Flexible Single Core Tinned Double Insulated (SDI) Cable
- SafeX125 Multi Core - LSZH 125°C - Tinned Copper Cables
- Sydney Trains - Multi-Core Power Cables
- Sydney Trains - Multi-Core Signal Cables
- Sydney Trains - Single Core Power Cables
- Traction Return Bonding and Track Connection
- VRIOGS Power and Signal Cables
- Rubber HO7 RN-F
- Silicone Rubber Cables 150 - 200
- Solar Cable
- Speaker Cable
- Telephone Cable
- Traffic Cables
Detecta-Cab - XLPE Insulated Loop Detector Traffic Cable
Application:
For use in inductive vehicle-detector loops within traffic signal installations
Benefits |
|
Type Approved |
Type approved in various states and territories |
Extra Heavy Duty |
Exceptional mechanical strength, impact and abrasion resistance |
High UV Resistance |
High carbon content insulation provides excellent UV protection |
Chemical Resistant |
Resistant to a range of chemicals |
Features |
Oxygen free tinned copper for high conductivity soldered connections and corrosion protection |
High temperature insulation for high ambient temperature applications |
Cross-Linked insulation for additional mechanical and thermal stability |
Construction |
|
Conductor |
Oxygen free tinned annealed copper wire, class 2 |
Insulation |
X-90UV |
Colour |
Black |
Ratings |
|
Temperature |
-10°C to + 90°C |
Voltage |
250/250V |
Applicable Standards |
AS/NZS1125, AS/NZS2276.3, AS/NZS3808, IEC 60228 |
Tinned Copper for Corrosion Resistance
Minimum Service Temperature -10°C
Maximum Service Temperature 90°C
Impact Resistant
Abrasion Resistant
Minimum Recommended Bend Radius Fixed 8 x OD
UV Resistant
Halogen Free
Bambach Product Specifications
Description | |
---|---|
Traffic Cable - Specification Sheet | Download |
Bambach Product Catalogue | Download |