back|Home / Mining Cable / Type 3 Machine Cable
Type 3 Machine Cable

For use where excess heat is generated at connection points. Cable can be used for control boxes, motors or resistor boxes fitted to mobile haulage machinery (shuttle cars). Cable is also designed to provide mechanical strength

Note: Cable has a maximum continuous operating temperature of 90°C, except for a short distance adjacent to the connecting terminals where the outer covering has been removed. Here the maximum permissible operating temperature is 150°C

Enquire Now


Abrasion Resistant
Abrasion Resistant
Chemical And Oil Resistant
Chemical And Oil Resistant
Flame Non-Propagation
Flame Non-Propagation
Flexible Conductor	Class 5
Flexible Conductor Class 5
Impact Resistant
Impact Resistant
Maximum Service Temperature 90°C
Maximum Service Temperature 90°C
Minimum Recommended Bend Radius Fixed	6 x OD
Minimum Recommended Bend Radius Fixed 6 x OD
Minimum Service Temperature -10°C
Minimum Service Temperature -10°C
Gas Non-Transmission Cables do not aid propagation of ignition source
Excellent Heat Resistance R-S-150 insulation provides outstanding long term performance in high temperature connections
Robust Construction Cores are taped and tightly braided to minimise damage from vibration
Extremely Flexible Flexible cable using class 5 conductors
Easy to Install Flexible insulation and sheath for use in confined applications
Excellent Screening Composite tinned copper and poly-yarn screening provides excellent mechanical strength with high coverage
Rated up to 150°C at connections
Fine conductor stranding for high flexing
RoHS compliant to European environmental requirements
Oxygen free tinned copper strands for high corrosion protection
Tinned copper braid with 90% minimum coverage provides excellent EMI and mechanical protection
Conductor Oxygen free tinned annealed copper wire, class 5
Insulation R-S-150
Screening Oxygen free tinned annealed copper wire inter woven with high tensile poly-yarn
Sheath 5V90 PVC
Colours Red, black, blue, white
Temperature -10°C to + 90°C
Voltage 1.1/1.1kV
Applicable Standards AS/NZS1125, AS/NZS1972, AS/NZS3808, AS/NZS60079.1 – Gas Group 1, AS/NZS1660.5.6, IEC 60228, IEC 60332-1
Max Conductor DC Resistance at 20°C 13.7Ω/km
Capacitance (Core - Core, 1kHz) 70pF/m
Products
Select Code Conductor CSA mm² STRANDING NOMINAL DIAMETER mm Rating Amps WEIGHT Kg/mtr Select
{{product.code}} {{product.description}} {{product.no_of_cores_x_conductor_csa_mm2}} {{product.no_of_pairs_x_conductor_od_mm}} {{product.no_of_pairs_x_conductor_csa_mm}} {{product.conductor_csa_mm}} {{product.conductor}} {{product.strands}} {{product.diameter}} {{product.diameter2}} {{product.rating}} {{product.weight}} {{product.construction}} {{product.core_dc_resistance_km}} {{product.capacitance_core_core_1khz_pfm}} {{product.capacitance_core_screen_1khz_pfm}} {{product.inductance_parallel_cores_1khz_hm}} {{product.lr_h}} {{product.average_insulation_thickness_mm}} {{product.application}}
Type 3 Machine Cable